DDBJ-350F Technical Parameters
| model | DDBJ-350F | |
| Instrument level | 1.0 level | |
| Measurement parameters | conductivity、resistivity、TDS、salinity value、temperature | |
| conductivity | Range | 0.000μS/cm~1000mS/cm |
| Minimum resolution | 0.001μS/cm,Automatic switching according to the range | |
| Electronic unit reference error | ±1.0% FS | |
| resistivity | Range | 5.00Ω・cm~20.00MΩ・cm |
| Minimum resolution | 0.01Ω・cm,Automatic switching according to the range | |
| Electronic unit reference error | ±1.0% FS | |
| TDS | Range | 0.000mg/L~300g/L |
| Minimum resolution | 0.001mg/L,Automatic switching according to the range | |
| Electronic unit reference error | ±1.0% FS | |
| salinity value | Range | (0.00~8.00)% |
| Minimum resolution | 0.01% | |
| Electronic unit reference error | ±0.2% | |
| temperature | Range | (-5.0~110.0)℃/(23.0-230.0)℉ |
| Minimum resolution | 0.1℃/0.1℉ | |
| Electronic unit reference error | ±0.2℃ | |
| power supply | Rechargeable lithium battery, power adapter (Input: AC100~240V, Output: DC5V) | |
| size(mm),weight(kg) | 90×255×40,0.5 | |
Main features:
- Adopts a high-definition color LCD touch screen with clear display
- Selectable temperature units: ℃ and ℉
- Reference temperature can be selected as 20℃ or 25℃
- Supports functions such as power-on self-diagnosis, automatic shutdown, power-off protection, and factory reset
- Supports firmware upgrade function, allowing function expansion and personalized requirements
- Supports IP65 protection rating
- Standard configuration includes composite conductivity electrode, electrode hanger, silicone protective cover, wristband, portable carrying case, and calibration solution
- Intelligent endpoint judgment, supporting automatic reading, timed reading, fixed-interval reading, and manual reading
- Supports automatic / manual temperature compensation
- Automatically identifies 4 types of GB conductivity standard solutions, supporting 1-3 point conductivity electrode calibration
- Supports multiple conductivity compensation methods such as no compensation, linear compensation, and pure water compensation
- Supports automatic frequency switching, and the matching electrode can cover the measurement range from 0.055μS/cm to the full range
- Supports data storage (1000 sets each), viewing, deletion, transmission, and printing
- Compliant with GLP to achieve data traceability
- Supports connecting to a standard RS-232 serial port printer to print measurement results, with selectable printing formats
- Equipped with a USB interface, which can connect to a PC through dedicated communication software to realize data transmission
- Powered by a large-capacity lithium battery, supporting charging via PC and mobile power supply
- Has battery undervoltage reminder function and charging status reminder function
- Supports backlight adjustment